Print

Dual Pump - 50Hz-60Hz - Operation Guide (oval)

Posted in Pumps & Motors

Dual-Pump-Tub-Controller-Balboa-Nordic-small

Pump Operation Guide For Systems Dual 50Hz/60Hz pumps.


Initial Start-up

Your spa will enter Priming Mode (Pr ) when it is energized.

During Priming Mode, press “Jets” button repeatedly and be sure the pump is free of air.

Priming Mode lasts less than 5 minutes. Press “Set” to exit. After Priming Mode, the spa will run in Standard Mode (see Mode section).

  • Pump 1 low-speed is responsible for heating and filtration and will be referred to simply as the pump.
  • In multi-button sequences, if the buttons are pressed too quickly in sequence, they may not register.
  • Low speed pump will run every 30 minutes from 2 to 5 minutes to check the tubs water

Temp Control (80°F - 104°F / 26°F - 40°F)

The last measured water temperature is constantly displayed. The water temperature displayed is current only when the pump has been running for at least 1 minute.

To display the set temperature, press “Warm” or “Cool” once.

To change the set temperature, press a temperature button again before the display stops flashing. Each press of “Warm” or “Cool” will adjust the set temperature. After three seconds, the display will stop flashing and begin to display the current spa temperature..

Jets

Jets 1

Press “Jets 1” to turn pump 1 on or off, and to shift between low and high speeds. The low-speed will turn off after 4 hours. High-speed will turn off after 15 minutes.

Low-speed may run automatically at times, during which it cannot be deactivated from the panel, but high-speed may be operated.

Jets 2

Press “Jets 1” to turn pump 1 on or off, and to shift between low and high speeds. The device will turn off after 15 minutes.

Light

Press “Light” to operate the spa light. Turns off after 4 hours.

Mode

Mode is changed by pressing “Warm” or “Cool,” then pressing “Mode.”

Standard Mode maintains set temperature. Std will be displayed momentarily when you switch into Standard Mode.

Economy Mode heats the spa to the set temperature only during filter cycles. Ecn will display when water temp is not current, and will alternate with water temp when the pump is running.

Sleep Mode heats the spa to within 20°F/10°C of the set temperature only during filter cycles. SLP will display when water temp is not current, and will alternate with water temp when the pump is running.

Preset Filter Cycles

The first preset filter cycle begins 6 minutes after the spa is energized.

The second preset filter cycle begins 12 hours later.

Filter duration is programmable for 2, 4, 6, or 8 hours or for continuous filtration (indicated by FILC ).

The default filter time is 2 hours.

To program, press “Warm” or “Cool,” then “Jets 1.” Press “Warm” or “Cool” to adjust. Press “Jets 1” to exit programming.

Low-speed pump 1 and the ozone generator (if installed) run during filtration